84 Chapter 7 Command Line Interface (CLI)

MFC directory

Table 25 includes the CLI commands for the configuration and control of MFC-R2 protocols. The commands are accessed from the MFC directory.

Table 25 MFC directory CLI commands (Sheet 1 of 3)

CLI command

Description

 

 

ICm <mfc_link>

Sets and displays incoming call timers.

<incoming_timer_type> <msec>

 

 

Where:

 

mfc_link is the number of required mfc/r2 links.

 

incoming_timer_type is one of the timers defined for incoming mfc call

 

processing.

 

msec is the time interval in msec.

 

 

OGm <mfc_link>

Sets and displays outgoing call timers.

<outgoing_timer_type> <msec>

 

 

Where:

 

mfc_link is the number of required mfc/r2 links.

 

outgoing_timer_type is one of the timers defined for outgoing mfc call

 

processing.

 

msec is the time interval in msec.

 

 

REgSign <mfc_link><rs_name>

Sets the register signaling

 

Where:

 

mfc_link is the number of the link, 0 or 1.

 

rs_name is the signaling type, 0 (MFC) or 1 (SMFC).

 

 

AniOption <mfc_link><flag>

Enables or disables the ANI option.

 

Where:

 

mfc_link is the number of the link, 0 or 1.

 

flag defines the ANI option as enabled (0) or disabled (1).

 

When disabled, ANI is not requested in incoming calls and not transmitted in

 

outgoing calls.

 

 

mfcINDia<flag>

Enables or disables the processing of the special MFC option for India.

 

Where:

 

flag defines the Special ANI digit option as enabled (0) or disabled (1).

 

When enabled, the prefix of one is expected on incoming calls and is

 

transmitted on outgoing calls.

 

 

NN40010-300

Page 84
Image 84
Nortel Networks R2MFC manual MFC directory CLI commands Sheet 1