36 Chapter 4 Installing the R2MFC MBM

Installing an R2MFC MBM in the BCM50 expansion unit

Perform the following steps to install an R2MFC MBM in the BCM50 expansion unit chassis. Install the R2MFC MBM when the system is powered down:

Caution: Only install the R2MFC MBM when the system is powered down. See “Shutting down the system” on page 32.

Warning: Failure to follow procedures to properly disconnect the BCM and expansion unit can result in module or system damage.

1Ensure that both the faceplate and underside DIP switches on the R2MFC MBM are set correctly. For information on how to set the faceplate switches, refer to “Setting Config DIP switches” on page 49. For information about how to set the underside switches, refer to the BCM Installation and Maintenance guide for the host system.

2With the faceplate of the R2MFC MBM facing toward you, insert the R2MFC MBM into the open bay. Ensure that any cables at the rear of the module are clear of the platform base chassis.

3Push the R2MFC MBM into the unit. You will hear a click when the module is firmly seated in the media bay.

Installing the rubber boot in an R2MFC module

Perform the following steps to install the rubber boot onto an R2MFC transmit or receive co-axial cable.