46Chapter 4 CS 1000 considerations

Table 8 S1000 Main Office Settings (Sheet 3 of 3)

Field

Values

Description

 

 

 

Node ID

9999 (default)

Automatically written to the IP telephone firmware

 

 

when the IP telephone registers with the main

 

Range: 0 to 9999

office.

 

Used to identify the node on the main office

 

 

 

 

associated with the IP telephone DN.

 

 

 

MO Access Code Length

For CDP dialing plans: set to 0

The number of digits to add to the BUID (DN) so

 

For UDP dialing plans: set to

the main office system can determine if the

 

incoming call is valid.

 

length of line pool access code or

 

 

 

destination code in front of LOC.

 

 

Range: 0 to 34

 

 

 

 

To datafill the S1000 Main Office Settings panel

1In Element Manager, navigate to Configuration > Resources > Survivable Remote Gateway (see the figure S1000 Main Office Settings panel on page 46).

2Select the S1000 Main Office Settings tab.

3Enter the information in the appropriate fields.

Figure 5 S1000 Main Office Settings panel

NN40140-500