Table 8 S1000 Main Office Settings (Sheet 2 of 3)

 

 

 

 

Field

Values

Description

 

 

 

H323 ID

SRG* (default)

Gatekeeper setting that identifies the SRG.

 

*This setting must be changed.

 

 

 

This value must match the value in the Alias

 

see the Networking Configuration

names field of the Local IP gateway:

 

Guide (NN40020-603) for naming

Configuration > Resources > Telephony

 

conventions.

 

Resources > Modules panel > Module type

 

 

 

 

column: select IP Trunks > Details for Module:

 

 

Internal details panel > Local Gateway tab >

 

 

Gatekeeper Support subpanel > Alias names

 

 

field (see VoIP trunking configuration on page 72).

 

 

The SRG acts as a SIP endpoint and obtains the

 

 

Main Office TPS IP address from the NCS using

 

 

the H323 ID.

 

 

Configure this field as the same SIP endpoint name

 

 

as you configure for the NRS endpoint name. This

 

 

is a generic field used for both SIP and H.323

 

 

virtual trunk configurations.

 

 

 

Numbering Plan ID

Unknown

The type of numbering plan at the main office.

 

ISDN/Telephony (E.164)

 

 

Private

 

 

Telephony (E.163)

 

 

Telex (F.69)

 

 

Data (X.121)

 

 

National Standard

 

 

Default: Private

 

 

 

 

Type of Number

Unknown

The main office dialing plan.

 

International Number

 

 

National Number

Ensure that the SRG private dialing plan is

 

Special Number

configured to match the selected value.

 

 

 

Subscriber Number

 

 

ESN LOC (UDP)

 

 

ESN CDP

 

 

ESN Special Number

 

 

Default: ESN CDP (for CDP dialing

 

 

plans) (BUID = DN)

 

 

UDP dialing plans: select ESN

 

 

LOC (UDP) (BUID = LOC+DN)

 

 

 

 