Chapter 4 CS 1000 considerations 49

Table 10 SRG S1000 IP Terminal Details fields (Sheet 2 of 2)

Field

Values

Description

 

 

 

Firmware

Read-only

Updated by the main office when a terminal is sent back to the SRG for

Version

 

firmware upgrade purposes. The field specifies the firmware version

 

 

required by the main office.

 

 

 

MOTN

XXX

Required for telephone redirection.

 

 

The field is the main office TN associated with the IP telephone.

 

 

 

BUID

CDP network: <DN>

Required for telephone redirection.

 

 

The field represents the dialable number of an IP telephone at the SRG

 

UDP network: <VoIP access

when it is called from a phone located at the main office or another

 

code> + <LOC> + <DN>

branch office.

 

 

The BUID at the SRG must be the same as the BUID at the main office.

 

 

 

MO TPS

Read-only

This field echoes the address of the main office terminal proxy server

 

 

when the IP telephone is redirected.

 

 

 

Note: The SRG DNs must be configured before the following procedures can be undertaken. See Telephone (DN) records configuration on page 56.

To enter the MOTN and BUID

1In Element Manager, navigate to Configuration > Resources > Survivable Remote Gateway.

2Select the S1000 IP Terminal Details tab (see the figure S1000 IP Terminal Details panel on page 50).

3Refer to the numbers and models recorded in the table IP telephone numbers and models on page 47.

4Select the required DN.

5Press the Modify button.

6Enter the MOTN and the BUID in the appropriate fields.

To redirect the telephone to the main office call server

1In Element Manager, navigate to Configuration > Resources > Survivable Remote Gateway.

2Select the S1000 IP Terminal Details tab (see the figure S1000 IP Terminal Details panel on page 50).

3Select the DN of the telephone to be redirected.

4Press the Redirect Set button.

SRG50 Configuration Guide