Rev 40672201TX.Fig

4.

-4

 

1/2-2-2

65 - 4

Control Mechanical 051-FX

 

Page) (Single Sequence

• S roller (includ feed, sensor and exit)

• Separation rubber

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• Exit pinch

 

 

 

 

• PC1

 

 

 

 

 

 

 

 

• PC2

 

 

 

• CIS

Mode

Pulse speed

Pulse

Feed Speed

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(l/mm)

(PPS)

Count

[mm/second]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• ADF roller

• First pinch roller

ON: 15.7 mm

 

 

3.85

800

4

52.0

 

 

 

 

 

 

 

 

21.2 mm

 

 

29.5 mm

 

4.5 mm

(OFF: 6.9 mm)

15.5 mm

 

7.7

800

2

52.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15.4

400

1

26.0

Numerical numbers are theoretical values.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

[Scanner section operation for single page copy and transmission]

 

 

 

 

 

 

 

* 1-2 phase drive (7.5°) motor constant voltage drive

 

 

* PC2 turn on within 10 seconds.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Document removal is shown on LCD for

 

 

 

 

 

 

* Reading length

 

 

* Throughing start is used for 600 PPS, 800PPS.

 

over 10 seconds.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10.6 mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7.7 mm

 

 

 

 

 

 

 

 

90.9 mm

 

 

 

 

 

 

1.3 mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(All keys operation are accepted during

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

the action.)

 

 

 

 

 

164 pulses

20 pulse

 

1400 pulses

 

 

 

 

 

 

 

 

 

 

* Sequence

 

118 pulse

 

 

 

 

 

 

 

* Reading starts

 

* Document exits: 600 PPS

 

 

 

 

Waiting

 

 

 

 

 

 

 

 

 

600 PPS

 

 

 

 

 

 

 

 

 

 

 

* Throughing:400 PPs x 20 pulses

*Throughing, then 800 PPS

400 PPS x 5 pulses to 600 PPS x 5 pulses

* PC1

Feeding starts after 800 ms from

* Machine returns to waiting state after 5 seconds.

(No motor excitation during waiting state)

PC1ON.

 

* S motor

* End

Motor may stop.

* PC2