8.1Power
8.1.1 AC Voltage Range
The machine will operate within A/B, as shown in Table
Table
Voltage | Nominal Value | MinimumValue | Maximum Value |
Range | (Volts) | (Volts) | (Volts) |
|
|
|
|
A: U.S./CANADA | 120 | 102 | 127 |
|
|
|
|
B: INT’L | 230 | 198 | *250 |
|
|
|
|
Note: The power supply will actually work at 264 volts, but the maximum value shows 250 volts according to PTT regulation.
8.1.2Frequency Range
The machine will operate on AC power having a frequency in the range of 49 to 61 Hertz.
8.1.3Transients
The machine will operate without error under the following conditions:
Dropouts: 10 msec (Period: 1 sec)
Noise: [without error]
500 V (Pulse width:100 ns/800 ns, Rising time: 1 ns) [without memory loss]
1000 V (Pulse width: 100 ns/800 ns, Rising time: 1 ns)
8.1.4Power Consumption
The machine will not exceed the maximum values shown in Tables
40672201TX Rev.4 | 8 - 1 |