2.2.2Service functions

1)Local diagnosis (Refer to Fig. 4-1-1/2)

Local diagnosis consists of a LED test, MF tone test, sensor test, H-MODEM TX/RX test, tone test and print test, including memorized test pattern printing, a memory check and a program version check.

2)RMCS

(i)The remote diagnosis consists of at least by current RMCS model 20 (Remote Management Center System)

3)Other functions

MDY/DMY switchable

Long document Scanning

Attenuator

NL equalizer

No paper/No toner RX

Sensor CAL.

Service bit

TIME/DATE print

Service default list

Machine configuration list

Echo Protection (Ignore 1st DIS/CED-DIS timer/Tone for echo)

Echo Protection setting includes the Ignore 1st DIS, CED-DIS timer to unity from three to one setting.

Detailed setting is shown below.

New setting

Echo Protection

OFF

ON

 

 

 

 

 

Ignore 1st DIS

OFF

ON

 

 

 

 

Current setting

CED-DIS timer

75 ms

1.5 s

 

 

 

 

 

Tone for echo

OFF

ON

 

 

 

 

40672201TX Rev.4

2 - 18