4.7.4Heater control

The temperature of the toner fixing heater is lowered in the standby state to reduce power consumption and heat generation. The heater control operation is shown below.

Heater start *

 

 

 

* The heater is started by call reception.

The preliminary procedure is performed and image data for the first page is received in this period.

Printing start

 

 

1st

 

Heater warming time

 

page printing

1st page ejection

 

 

 

 

(seconds typ.)

 

 

 

 

 

 

 

Approx.seconds

The printer is normally placed in the standby.

If a call is received in this state, the heater is started; however, it takes a typically of 20 seconds for start printing. (This does not make longer the transmission time for document images such as ITU No. 1 sample document because, when a call is received the heater turned to ON, and printing of the first page starts after the preliminary procedure is per- formed and received image data.)

4.7.5Warming up of the printer

The printer starts the warm-up sequence to warm the toner fixing heater immediately after the power is turned on.

4.8Other Functions4.8.1Language

Selection of 2 languages shown on LCD and printed on reports is available to the user. Language selection is available for destination.