Omnitron Systems Technology RS-232 Read Five-Digit Addendum Do Not Read Five-Digit Addendum

Models: RS-232

1 71
Download 71 pages 18.42 Kb
Page 32
Image 32

Read Two-Digit Addendum

If enabled, the reader will decode the two-digit secondary symbol when it is scanned with the primary symbol, and add the data to the end of the transmis- sion. If not, any two-digit secondary symbol will be ignored.

SELECTION CODE: G2

 

Read Two-Digit Addendum

I

Do Not Read Two-Digit Addendum

J

Read Five-Digit Addendum

This option operates in the same manner as the Read Two Digit Addendum option except it enables the reading of a five digit secondary symbol.

SELECTION CODE: G2

Read Five-Digit Addendum

K

Do Not Read Five-Digit Addendum

L

Addendum Required

If a two or five-digit addendum is enabled, then enabling this option will require an addendum be present before a good read is registered. If not, then symbols with and without the addendum will be accepted.

SELECTION CODE: G2

 

Addendum Required

M

Addendum Not Required

N

Add Separator Space

This option is used with the Two and Five-Digit Addendum options. If en- abled, an ASCII space character is inserted between the data decoded from the primary UPC symbol and the addendum symbol.

SELECTION CODE: G2

 

Add Space Separator

O

Not Add Space Separator

P