5.If UNMATCHED INPUT is set to SEND, the unmatched data is passed on to the message processing section of the reader, where any previously-defined postamble, preamble, and terminator characters are added before the data is sent to the output port.

Examples

EXAMPLE ONE

76440057320712

Symbology Code 128

Desired Output: Divide the input data record into two fields with one consist- ing of the first six digits and the second containing the remaining data. The output should have a <CARRIAGE RETURN> or <CR> inserted after each field.

Formula

ID h C 06 A <ENTER> SEND ACBC

Field List

Field A 764400

 

 

 

Field B 57320712

 

Field C <CR>

 

 

 

 

Keystroke Sequence

 

Enter Data Editing Setup

 

/E/D/FJ<ENTER>

Enable Data Editing

 

JA<ENTER>1<ENTER>

Enter Code ID as h (for Code 128)

JC<ENTER>h<ENTER>

Define first six characters as Field A,

 

 

and remaining data as Field B

JF<ENTER>0<ENTER>

 

 

6<ENTER>

Enter Add Field C as the <ENTER> key

JJ<ENTER>^N<ENTER>*

Define Field Sending Sequence of ACBC

JK<ENTER>A<ENTER>

 

 

C< ENTER>B<ENTER>

 

 

C<ENTER>

Save Exit Setup

 

JZ<ENTER>

Output Data

 

764400<CR>

 

 

57320712<CR>

*^N: Do a CTRL-N by holding down the <CTRL> key while pressing the N key, then releasing both.

41

Page 47
Image 47
Omnitron Systems Technology RS-232 user manual Examples, Symbology Code