Omnitron Systems Technology RS-232 Set the Sequence in which Data Fields are Sent, Time Delay

Models: RS-232

1 71
Download 71 pages 18.42 Kb
Page 45
Image 45

Set the Sequence in which Data Fields are Sent

This command specifies the order in which data fields are transmitted to the host. Each separate field is assigned an upper case alpha letter in the order in which it is created. So the first data field created is A, the second is B, and so on.

SELECTION CODE: JK

Characters Assigned to Data Fields in the Transmission Order Desired

EXAMPLE:

To transmit fields A, B, and C to the host so that the second and third data fields are reversed, enter:

... JK<ENTER>A<ENTER>C<ENTER>B<ENTER> ...

This means that data fields A, B, and C will be transmitted as A, C, and B.

Time Delay

In addition to specifying the order in which data fields are transmitted to the host, you can add a time delay between each field. The amount of time delay is two digits multiplied by 100 milliseconds. So if the time delay specified is “02” the time delay will be 200 milliseconds.

SELECTION CODE: JM

Two Digits for Time Delay

Delete One Formula

This command deletes a single formula stored in the reader’s memory. To do this, you need to know the place the formula is stored in memory. In other words, if the formula to be deleted is the third formula stored in the reader’s memory, then you’ll need to enter the number 3.

SELECTION CODE: JS

One Digit to Indicate which Formula to Delete

39

Page 45
Image 45
Omnitron Systems Technology RS-232 Set the Sequence in which Data Fields are Sent, Time Delay, Delete One Formula