Reset Data Editing Group
This command will clear the reader’s memory of all formulas, disable the Data Editing feature, and send the original data with the preamble, postamble, and terminator specified.
SELECTION CODE: JX
EXAMPLE:
To delete all data editing formulas from the reader’s memory, enter: /E/D/FJ<ENTER>JX<ENTER>JZ<ENTER>
Review Configurations
This command allows you to view all the data editing formulas stored in the reader’s memory, as well as all other data editing settings.
SELECTION CODE: JY
EXAMPLE:
To view all data editing formulas in the reader’s memory, enter:
... JY<ENTER> ...
Exit Data Editing Mode
Remember to enter JZ<ENTER> to save your settings and exit the Data Editing mode.
SELECTION CODE: JZ
Omni Data Flow
The Omni reader processes scanned data in the following order:
1.Raw data is scanned and decoded and placed in an ASCII character format in the reader’s memory.
2.The bar code symbology and magnetic stripe track tests (maximum/ minimum length, check digit, send sentinels, etc.) are applied to the data.
3.Following the successful completion of these tests, the data is compared to each data editing formula stored in memory.
4.If the data matches one of the data editing formulas, it is processed and sent to the output port. If the data does not match any of the formulas and the UNMATCHED INPUT function is set to DO NOT SEND, the data will be discarded.