8. Accessing the MAIN Menu

8. Accessing the MAIN Menu

The MAIN Menu allows the user to adjust and calibrate the FLEXmax 80 for maximum performance. From the STATUS screen, press the first soft key on the left to open theMAIN Menu screen.

GCharger Aux Light EQ Misc Advanced Logging Stats

EXIT F G GO

Press GCharger Aux Light EQ Misc Advanced Logging Stats or •Charger—CHARGER SETUP to move the "•Aux—AUX OUTPUT CONTROL“ to the left of the desired screen. The arrow allows access to any screen to its right.

Press the <GO> soft key after aligning the arrow in front of the selected menu choice.

Pressing the <EXIT> soft key in the MAIN Menu returns to the STATUS screen.

From the MAIN Menu, a user can choose among the following FLEXmax 80 functions by aligning the arrow:

Charger—CHARGER SETUP

-Adjusts the Current Limit, Absorb, and Float recharging voltage set points

Aux—AUX OUTPUT CONTROL

-Secondary control circuit for a vent fan, error alarm, and other system-related additions

Light—BACKLIGHT CONTROL

-Adjusts the backlighting of LCD screen and soft key buttons

EQ—BATTERY EQUALIZE

-Activates battery equalization recharging (manually or automatically)

Misc—MISCELLANEOUS

-Additional settings and service information

Advanced —ADVANCE MENU

-Optimizing/fine-tuning the FLEXmax 80 (these are advanced Menus that should be left alone until the user has a good working knowledge of the FLEXmax 80 and its operations)

Logging—DATA LOGGING

-Displays recorded power production information

STATS—Statistics

-Displays recorded peak system information and cumulative kilowatt hours and amp hours