Outback Power Systems 80 STANDARD vs. AUSTRALIAN DEFAULT SETTINGS, Standard Version, Australian

Models: 80

1 92
Download 92 pages 41.02 Kb
Page 77
Image 77
28. STANDARD vs. AUSTRALIAN DEFAULT SETTINGS

28. STANDARD vs. AUSTRALIAN DEFAULT SETTINGS

The Australian version FLEXmax 80 has a few default settings that differ from the Standard version default settings. However, there are no differences in performance and efficiency between the two versions. The Standard and Australian version can be identified as follows:

OutBack

12V

OutBack

12V

 

Power

Power

Systems

 

Systems

FLEXmax 80-AU

FLEXmax 80

 

 

Standard Version

Australian Version

Below are a few default setting differences between the Standard and Australian version.

Settings

Standard

Australian

Charger

Absorb

Float

Absorb

Float

12V

14.4V

13.6V

14.4V

13.8V

24V

28.8V

27.2V

28.8V

27.6V

36V

43.2V

40.8V

43.2V

41.4V

48V

57.6V

54.4V

57.6V

55.2V

60V

72.0V

68.0V

72.0V

69.0V

Equalize

Equalize Volts

Equalize Volts

12V

14.4

14.7

24V

28.8

29.4

36V

43.2

44.1

48V

57.6

58.8

60V

72.0

73.5

Equalize Time

01 Hours

03 Hours

76

Page 77
Image 77
Outback Power Systems 80 user manual STANDARD vs. AUSTRALIAN DEFAULT SETTINGS, Standard Version, Australian