GT

State

PWM%

ChgT

 

255

07

50.0

005

Press the <NEXT> soft key to view the FORCE FLOAT, or

 

 

 

 

 

 

 

 

BULK screen.

EXIT

NEXT

 

RSTRT

 

 

 

 

 

Pressing the <FLOAT> or <BULK> soft key forces the

 

 

 

 

FLEXmax 80 to that specific recharging cycle and returns

 

FORCE

to the STATUS screen. Forcing a FLOAT or BULK recharge

 

will end an EQ cycle. Press the <NEXT> soft key to view

EXIT NEXT FLOAT BULK

the third MISCELLANEOUS screen.

 

 

 

 

 

 

 

 

• Force FLOAT = float cycle

 

 

 

 

• Force BULK = bulk cycle

 

 

 

 

 

 

 

 

This is the assigned number representing

Btmp is a battery temperature sensor reference

the temperature of the internal components

value used to compensate the charging voltage.

to control the cooling fan. The lower the

This is an arbitrary number between 0 and 255

number, the higher the temperature. 25° C is

and is not the actual temperature. An ‘X’ next

approximately a value of 525.

 

to this value indicates a Global external RTS is

 

 

being used (system with a HUB and MATE).

PCB

Target

Btmp

CFB

The output value of the

internal current sensor is

512

14.4v

255

0712

used to calculate output

The target voltage the

 

 

 

 

 

 

amps, watts, and track

controller is trying to reach. EXIT

BACK

 

 

 

 

the Maximum Power

Point of the array.

Press the <EXIT> soft key twice to return to the MAIN

MENU.

44

Page 45
Image 45
Outback Power Systems 80 user manual Pwm%, Force, Exit Next Float Bulk, Pcb, Cfb