LOW BATTERY DISCONNECT
AUX MODE |
|
|
|
| |
Low Batt Disconnect |
|
|
|
| |
Output: On | On |
|
|
| On |
|
|
| |||
EXIT NEXT | SET MODE |
|
|
| Off |
|
|
| |||
|
|
|
|
| Auto |
AUX MODE
Low Batt Disconnect
When the battery voltage falls below the disconnect volts, the AUX connected loads only are disconnected; the AUX connected loads only are connected when the battery voltage rises above the reconnect volts. To adjust these set points, press the <TIME> and <VOLT> soft keys.
Press the <TIME> and <VOLT> soft keys to adjust the set points.
EXIT | TIME VOLT |
Delay Time Sec
01Timer 001
BACK - +
Press either the < - > or < + > soft key to adjust the delay time. This is the time period the FLEXmax 80 waits before either activating or deactivating the AUX MODE when either the disconnect or reconnect voltages are reached. When the low voltage occurs, the timer shows the seconds remaining before disconnecting. When the reconnect voltage is reached, the timer shows the
37