Outback Power Systems 80 user manual ADVANCED MENU RTS Compensation A 14.4 V F EXIT NEXT LIMIT SET

Models: 80

1 92
Download 92 pages 41.02 Kb
Page 52
Image 52
ADVANCED MENU

ADVANCED MENU

RTS Compensation

A 14.4 V F 13.8V

EXIT NEXT LIMIT SET

AUTO RESTART

ADVANCED MENU

Auto ReStart

MODE 2

EXIT NEXT MODE

ADVANCED MENU

Auto ReStart

MODE 0

EXIT NEXT MODE

ADVANCED MENU

Auto ReStart

MODE 1

EXIT NEXT MODE

Press the <NEXT> soft key to view the Auto Restart screen.

Pressing the fourth soft key selects among the three FLEXmax 80 Auto ReStart modes: 0 (default), 1, and 2. Auto ReStart allows the FLEXmax 80 to perform internal recalibrations.

Mode 0Auto ReStart mode is disabled; the FLEXmax 80 recharges continuously from an available source and never Restarts. Mode 0 would be chosen to avoid spinning a microhydro generator every 1.5 hours.

Mode 1—once every 1.5 hours, when the FLEXmax 80 is in Bulk, it will briefly Restart and initiate a full panel tracking. This will not reset any counters or charging stages or statistics.

Mode 2Auto ReStart every 1.5 hours; in Bulk, Absorb, and Float modes, it will briefly Restart and initiate a full panel tracking. This will not reset any counters or charging stages or statistics.

51

Page 52
Image 52
Outback Power Systems 80 ADVANCED MENU RTS Compensation A 14.4 V F EXIT NEXT LIMIT SET, Auto Restart, Exit Next Mode