3. FLEXmax 80 Wiring Connections
Figure 1 FLEXmax 80 wiring compartment
Use up to 2 AWG (33.6 mm2) wire and torque to
MATE/HUB
RJ45 jack
Battery Remote Temp Sensor (RTS) RJ11 jack
Programmable AUX Output Jack (supplies up to 200mA @ 12 VDC
PV+ PV- BAT- BAT+
Wire Lugs
Chassis/Equipment
Ground Lug
Screw holes for attaching FLEXmax 80
The PV
NOTES:
•Each FLEXmax 80 requires its own PV array. DO NOT PARALLEL FLEXmax 80 PV+ and PV- TERMINALS ON THE SAME ARRAY!
•An optional battery Remote Temperature Sensor (RTS) is recommended for accurate battery recharging (only one RTS is needed for multiple OutBack Series Inverter/Chargers and FLEXmax 80 units when an OutBack HUB and a MATE are parts of the system). When one RTS is used, it must be connected to the component plugged into the Port 1 of the HUB.