ADVANCED MENU

Auto ReStart

MODE 2

EXIT NEXT MODE

ADVANCED MENU

Aux Polarity

G Active High

EXIT NEXT

MODE

ADVANCED MENU

Aux Polarity

G Active Low

EXIT NEXT

MODE

ADVANCED MENU

Reset to Defaults?

EXIT NEXT

RESET

From the Auto Restart MODE 2 screen, press the <NEXT> soft key to view the Aux Polarity screen.

When the AUX function is ON, 12 volts is present at the AUX terminal; when it’s OFF, 0 volts are present at the terminal. Aux Polarity allows the user to reverse the availability of this voltage for the Night Light, PV Trigger, or Diversion Relay functions. In Active High, the user establishes certain conditions for these functions. Pressing the <MODE> soft key brings up the Active Low screen which allows the user to reverse these conditions.

In the Active Low zero voltage will be available for a function that in Active High would normally have voltage. When one of the three functions— Night Light, PV Trigger, or Diversion Relay—has been chosen as the AUX function, an arrow in the right hand corner of the screen will reflect the Aux Polarity state. An arrow pointing up means Active High while an arrow pointing down means Active Low. Press the <NEXT> soft key to view the Reset to Defaults? screen.

EXAMPLE

AUX MODE

G

 

AUX MODE

G

 

PV Trigger

 

 

PV Trigger

 

 

Output: Off

Off

 

Output: Off

Off

 

EXIT NEXT SET MODE

 

EXIT NEXT SET MODE

 

 

 

 

 

 

PV Trigger Active High

 

PV Trigger Active Low

In this screen, a user can press the <RESET> soft key to return the FLEXmax 80 to the factory default settings.

(If you do not need to reset, press the <EXIT> soft key to return to the STATUS screen.)