AUX MODE | G | |
Night Light | ||
|
EXIT HYST TIME VOLT
Press the <EXIT> soft key to return to the Night Light AUX mode.
AUX MODE | G | ||
Night Light | |||
| |||
Output: Off | Auto |
| |
EXIT NEXT | SET MODE |
FLOAT
AUX MODE
Float |
|
|
Output: Off | Off |
|
| ||
EXIT NEXT | SET MODE |
RELAY |
|
|
AUX MODE | G | |
Diversion: Relay |
|
|
Output: Off | Off |
|
| ||
EXIT NEXT SET | MODE |
On
Off
Auto
On
Off
Auto
Press the <NEXT> soft key ro view the AUX Float screen.
The AUX MODE is active when the FLEXmax 80 is in Float and producing power. Press the <NEXT> soft key to advance to the Diversion screen.
When external DC sources (wind, hydro) are directly connected to a battery bank, any excess power should be sent to a diversion load, such as a heat- ing element, via a mechanical or solid state relay.
In Diversion, which features Relay and Solid State screens, the user programs set
This is primarily an