System Voltage Screen
SYTEM VOLTAGE
12 24 36 48 60
^^
GENTER
Press the <YES> soft key to confirm your choice or <NO> to return to the SELECT VERSION screen.
The FLEXmax 80 auto detects the system’s battery voltage. To confirm this voltage, press the<ENTER> soft
key. If incorrect, press the “G” soft key to select a battery voltage. The FLEXmax 80’s default values are based on a 12VDC system. Selecting a higher voltage system will change all the default values (e.g., the values will double with a 24VDC system, triple with a 36 VDC system, etc.). “^^” indicates the chosen voltage. The FLEXmax 80 will automatically accept the selected battery voltage if left unattended for 5 minutes in this screen. After choosing the voltage, press the <ENTER> soft key to proceed.
Verification Screen
Are you sure? 12 24 36 48 60
^^
NOYes
Press the <YES> soft key to proceed if the selected battery voltage is correct. If incorrect, press <NO> to re- enter the correct voltage. The <YES> soft key will open the STATUS screen.
Note: Repeating the Powering Up sequence resets the FLEXmax 80 Charge Controller to its factory default settings (see page 76).
18