Adjusting the white balance and black balance
To record
If white balance and black balance adjustments are made while the video image is distorted due to GENLOCK, the adjustments may not be correct. Wait for the video image to return to normal before performing white balance and black balance adjustments again.
Adjusting the white balance
Whenever light conditions change, the white balance must be readjusted.
To adjust the white balance, follow the steps on the right.
ND FILTER dial
This control adjusts the amount of light entering the MOS sensor.
1 Set the GAIN and WHITE BAL switches.
•For the WHITE BAL switch, select A or B as a position to save the adjustment value.
2 Adjust the ND FILTER dial according to the light conditions.
For examples of ND FILTER dial, see “Light intensity adjustments” (Page 31).
3 Place a white pattern at a point where the light conditions match those for the light source of the subject. Then
•A white object (cloth or wall) may be used instead of a white pattern. The illustration below shows the required size for the white space.
•Do not point the
•The white object must appear at the center of the screen.
1/3 or more of the screen in width
AWB button | WHITE BAL switch |
Use for automatic control | Set to A or B. |
of white balance. |
|
GAIN switch
Normally set to 0 dB. If this is too dark, adjust gain as necessary.
1/3 or more of the screen in height
4 Adjust the lens iris.
•Use the Y GET function (Page 122) and adjust the iris to a approximately 70 % of incoming light.
5 Press the AWB button.
•The switch returns to the central position with the white balance automatically adjusted.
6 During an adjustment, the viewfinder or LCD monitor displays the following message:
AWB Ach ACTIVE
32