Error messages (continued)

Error messages (continued)

Display

z Description

z VTR operation and remedial action

 

 

 

E-51

If the take-up reel has turned without engaging

FRONT LOAD

the tape for a specific period of time during the

ERROR

tape start or end processing operation while

 

loading is being performed (at the half position),

 

the AUTO OFF lamp lights, and the message

 

display blinks.

 

VTR: Stops.

 

z Set the POWER switch to OFF and then back to

 

ON again.

 

 

E-52

If, after the cassette has been inserted, the tape

W-UP REEL

take-up reel has not wound up the tape while the

NOT ROTA

total tape amount is not detected and while the

 

tape is traveling, the AUTO OFF lamp lights, and

 

the message display blinks.

 

VTR: Stops.

 

z Set the POWER switch to OFF and then back to

 

ON again.

 

 

E-53

If, after the total tape amount has been detected,

WINDUP

the amount of tape wound up onto the take-up

ERROR

reel and the amount of tape supplied by the

 

supply reel differ to an abnormal extent while the

 

tape is traveling, the AUTO OFF lamp lights, and

 

the message display blinks.

 

VTR: Stops.

 

z Set the POWER switch to OFF and then back to

 

ON again.

 

 

E-55

If the tape has not been wound up during

UNLOAD

unloading, the AUTO OFF lamp lights, and the

ERROR

message display blinks.

 

VTR: Stops.

 

z Set the POWER switch to OFF and then back to

 

ON again.

 

 

E-57

When the tape start or end processing operation is

S-FF/REW

not completed, the AUTO OFF lamp lights, and the

TIMEOVER

message display blinks.

 

VTR: Stops.

 

z Set the POWER switch to OFF and then back to

 

ON again.

 

 

E-59

If the rotational speed of the cylinder motor is

DRUM ROTA

abnormally slow, the AUTO OFF lamp lights, and

TOO SLOW

the message display blinks.

 

VTR: Stops.

 

z Set the POWER switch to OFF and then back to

 

ON again.

 

 

E-60

If the rotational speed of the cylinder motor is

DRUM ROTA

abnormally high, the AUTO OFF lamp lights, and

TOO FAST

the message display blinks.

 

VTR: Stops.

 

z Set the POWER switch to OFF and then back to

 

ON again.

 

 

E-61

If the rotational speed of the cylinder motor is

CAP ROTA

abnormally slow, the AUTO OFF lamp lights, and

TOO SLOW

the message display blinks.

 

VTR: Stops.

 

z Set the POWER switch to OFF and then back to

 

ON again.

 

 

E-64

If the supply reel motor rotates at an abnormally

S REEL ROTA

fast rate, the AUTO OFF lamp lights, and the

TOO FAST

message display blinks.

 

VTR: Stops.

 

z Set the POWER switch to OFF and then back to

 

ON again.

 

 

E-67

If the take-up reel motor rotates at an abnormally

T REEL ROTA

fast rate, the AUTO OFF lamp lights, and the

TOO FAST

message display blinks.

 

VTR: Stops.

 

z Set the POWER switch to OFF and then back to

 

ON again.

 

 

Display

z Description

z VTR operation and remedial action

 

 

 

E-69

If an abnormal torque applied to the supply reel

T REEL

motor is detected or if an abnormal current flowing

TORQUE ERR

to the current-sensing resistor is detected, the

 

AUTO OFF lamp lights, and the message display

 

blinks.

 

VTR: Stops.

 

z Set the POWER switch to OFF and then back to

 

ON again.

 

 

E-70

When the tape start or end processing operation is

S REEL

not completed, the AUTO OFF lamp lights, and the

TORQUE ERR

message display blinks.

 

VTR: Stops.

 

z Set the POWER switch to OFF and then back to

 

ON again.

 

 

E-71

If an abnormal tension is detected at the supply

CAP TENSION

side in the capstan mode, the AUTO OFF lamp

ERROR

lights, and the message display blinks.

 

VTR: Stops.

 

z Set the POWER switch to OFF and then back to

 

ON again.

 

 

E-72

If an abnormal tension at the supply side is

REEL

detected in the reel mode, the AUTO OFF lamp

TENSION

lights, and the message display blinks.

ERROR

VTR: Stops.

z Set the POWER switch to OFF and then back to

 

 

ON again.

 

 

E-73

If the take-up reel motor is running in the reverse

REEL DIR

direction, the AUTO OFF lamp lights, and the

UNMATCH

message display blinks.

 

VTR: Stops.

 

z Set the POWER switch to OFF and then back to

 

ON again.

 

 

E-74

If excess torque being applied to the cylinder motor

DRUM

is detected, this error number flashes on the

TORQUE

display.

ERROR

VTR: Stops.

 

z Set the POWER switch to OFF and then back to

 

ON again.

 

 

E-FF

If the tape start and tape end are detected at the

 

same time either during or after loading, the AUTO

 

OFF lamp lights, and the message display blinks.

 

VTR: Stops.

 

z Set the POWER switch to OFF and then back to

 

ON again.

 

 

If the error message display persists even after the VTR has been shut down and started up again, consult your dealer.

130