RS-232C interface
The VTR can be operated by commands when the
_Condition for acknowledging commands from RS-232C interface
Setup menu item No.204
(RS232C SEL):ON
If the above condition is not met, [ACK]+[STX]ER001[EXT] is returned to the external component. Whether [ACK] is returned depends on the setting which has been selected for setup menu item No.209 (RETURN ACK).
Hardware specifications
External interface specifications
zConnector pin specifications
Connector:
Pin No. | Signal | Description |
|
|
|
|
|
|
1 | FG | Protective ground (frame ground) |
|
|
|
2 | RXD | Received data (data is sent to PC) |
|
|
|
3 | TXD | Transmitted data (data is received from |
|
| PC) |
4 | CTS | Clear to send (shorted with pin 5) |
|
|
|
5 | RTS | Request to send (shorted with pin 4) |
|
|
|
6 | DTR | Data terminal ready (no processing) |
|
|
|
7 | SG | Signal ground |
|
|
|
20 | DSR | Data set ready (+ voltage output after |
|
| communication enable status) |
zExample of connection with controller (PC)
(Using crossover cable with
PC side |
|
|
|
| |
VTR side | |||||
|
|
|
|
|
|
| FG | 1 |
| 1 | FG |
|
| ||||
| TXD | 2 |
| 2 | RXD |
| RXD | 3 |
| 3 | TXD |
| RTS | 4 |
| 4 | CTS |
| CTS | 5 |
| 5 | RTS |
| DSR | 6 |
| 6 | DTR |
| SG | 7 |
| 7 | SG |
| DTR | 20 |
| 20 | DSR |
|
|
|
|
|
|
(Using crossover cable with
PC side |
|
|
|
| |
VTR side | |||||
|
|
|
|
|
|
| RXD | 2 |
| 1 | FG |
| TXD | 3 |
| 2 | RXD |
| DTR | 4 |
| 3 | TXD |
| SG | 5 |
| 4 | CTS |
| DSR | 6 |
| 5 | RTS |
| RTS | 7 |
| 6 | DTR |
| CTS | 8 |
| 7 | SG |
|
|
|
| 20 | DSR |
|
|
|
|
|
|
131