Setup menus (continued)

<INTERFACE>

No./Item

 

Description of setting

 

 

200

For selecting whether to operate two or more

 

VTRs in synchronization.

PARA RUN

0000

DIS

 

The VTRs are not operated in synchronization.

 

0001

ENA

 

The VTRs are operated in synchronization.

 

<Note>

 

To operate the VTRs in synchronization, set all the

 

VTRs to 1 (ENA). (Refer to page 16.)

 

 

202

For setting what ID information is to be

 

returned to the controller.

ID SEL

0000

OTHER

 

For setting the ID information of a VTR other

 

than DVCPRO

 

0001

DVCPRO

 

For setting the ID information of the DVCPRO

 

0002

ORIG

 

Set only for connecting with the Panasonic

 

controller (AG-A850, optional).

 

 

204

For selecting whether the RS-232C connector is

 

to function.

RS2323C SEL

0000

OFF

 

The RS-232C connector does not function.

 

0001

ON

 

The RS-232C connector functions.

 

 

205

For setting the RS-232C data transfer speed

 

(baud rate).

BAUD RATE

0000

300

 

 

0001

600

 

0002

1200

 

0003

2400

 

0004

4800

 

0005

9600

 

 

206

For setting the RS-232C data length.

 

(Unit: bits)

DATA

0000

7

LENGTH

 

0001

8

 

 

207

For setting the number of RS-232C stop bits.

 

(Unit: bits)

STOP BIT

0000

1

 

 

0001

2

 

 

208

For setting whether the RS-232C parity bit is to

 

be used and, if it is used, whether even or odd

PARITY

parity is to apply.

 

0000

NON

 

The parity bit is not used.

 

0001

ODD

 

The parity bit is used with an odd parity.

 

0002

EVEN

 

The parity bit is used with an even parity.

 

 

 

The underlining (__) denotes the factory setting mode.

No./Item

 

Description of setting

 

 

209

For setting whether or not to return the ACK

 

code when a command is received from RS-

RETURN ACK

232C.

 

 

0000

OFF

 

The ACK code is not returned

 

0001

ON

 

The ACK code is returned.

 

 

212

For selecting the remote control connector for

 

controlling the slave machine when this VTR is

MASTER

to be used as the master machine for deck-to-

PORT

deck operations.

 

0000

IN/OUT

 

The IN/OUT connector is used.

 

0001

OUT

 

The OUT connector is used.

 

<Note>

 

This setting takes effect only when the 9P button

 

has been set to LOCAL (LED off).

 

 

 

90