Function menus (continued)
This enables confirmation of information such as the
Verification, deletion of the error log file, retention/call to the SD memory card can do with the SHIFT picture.
Warning mark
SHIFT F1 F2 F3 F4 F5 F6
Warning displayWhen a warning occurs in this VTR, the warning mark (W) blinks at the top left of the screen. If F1 (WARN) is now pressed, the details of the warning can be checked out on the LCD monitor.
When more than one warning has occurred, turn the ADJ dial to scroll through the messages.
When F2 (HOURS) is pressed, the
Press F2 (UMID) to confirm the current UMID information for the image on the LCD monitor.
UMID INFO | ||
MATNO | 00001234005678BA | |
COPY | 00B0458201000001 | |
0 |
| |
OWNR | JPN :ORG :USER | |
POS | ±3775m 3D | |
| E 180'00'00.0' | |
DATE | N | 90'00'00.0' |
TIME | 23:30:30 +03h00m |
Press F4 (DIF1) or F5 (DIF2) to display the different kinds of information about the current DIF (IEEE 1394 interface).
DIF STATUS 1 | DIF STATUS 2 | |||||
NODE CNT | 1 | <INPUT> |
| <OUTPUT> | ||
FMT |
| FMT | HD100 | |||
MY ID | 0 | RATE |
| RATE | 1X | |
ROOT ID | 0 | N/P | 63 | N/P | NTSC | |
IRM ID | 0 | CHN | CHN | 63 | ||
SPEED |
| SPEED | 400 | |||
RCV ID | 0 | STOP | ||||
STAT | START | OK | ||||
GAP CNT | 63 | VIDEO |
| VIDEO | OK | |
0080458200000000 | AUDIO |
| AUDIO | OK |
The error log mode can be selected by pressing the SHIFT button and switching the screen to <DIAG SHIFT>.
SHIFT F1 F2 F3 F4 F5 F6
When the following warnings have occurred while the tape is running, the warning messages, time codes and operating modes are saved, and a list of this information can be read out on the LCD monitor. Up to 99 warnings which have occurred can be saved. If the storage capacity of 99 warnings is exceeded, the processing that is conducted as a result is based on the setup menu item No.015 (AUTO STEP) setting.
Warning messages | Description |
which are saved | (Refer to page 129 and following.) |
| |
|
|
NO RF | A blank section on the tape lasting more than |
| 1 second has been detected. (During normal |
| playback) |
|
|
SV NOT LOCKED | The servo has been disengaged for more |
| than 3 seconds. (During recording, normal |
| playback or editing) |
|
|
LOW RF | An envelope level which is about 1/3 of nor- |
| mal or a CTL level which is about 1/6 of nor- |
| mal has been detected for more than 1 |
| second. (During recording, normal playback |
| or editing) |
|
|
HIGH ERROR RATE | The error rate has deteriorated, and correc- |
| tion or compensation has been applied to the |
| video or audio playback signals. (During nor- |
| mal playback) |
|
|
Operation mode display
Saved warning status display
Time code display
Warning display
Operation mode displayThis indicates the operation mode at the point when the warning was saved.
Warning display
This indicates the warning message which is saved.
Saved warning status displayThis indicates the number of the currently displayed warning which has been saved and the total number of warnings which have been saved.
Time code display
This indicates the time code at the point when the warning was saved.
Cueing up the tape to the warning pointThe warning list displayed on the LCD monitor can be scrolled by turning the ADJ dial. When the warning occurrence point to be checked is selected and the PREROLL button is pressed, the tape is cued up to the position of the time code which has been saved.