Setup menus
<INTERFACE>
No./Item |
| Description of setting | |
|
| ||
|
| ||
200 | For selecting whether to operate two or more | ||
| VTRs in synchronization. | ||
PARA RUN | 0000 | DIS: | The VTRs are not operated in |
|
|
| synchronization. |
| 0001 | ENA: | The VTRs are operated in |
|
|
| synchronization. |
| <Note> |
|
|
| To operate the VTRs in synchronization, set all the | ||
| VTRs to 1 (ENA). (Refer to pages 14 and 19.) | ||
|
| ||
202 | For setting what ID information is to be | ||
| returned to the controller. | ||
ID SEL | 0000 | OTHER |
|
| 0001 | DVCPRO |
|
| 0002 | ORIG |
|
| <Notes> |
| |
| • For 0 (OTHER), the ID information of VTRs other than | ||
| DVCPRO models is set. | ||
| • Select 2 (ORIG) only when the VTR is connected to a | ||
| Panasonic controller (such as the | ||
| optional accessory). | ||
| • Select 1 (DVCPRO) or 2 (ORIG) if the 23/24 Hz mode | ||
| has been selected by system menu item No.25 | ||
| (SYSTEM FREQ). | ||
|
| ||
204 | For selecting whether the | ||
| is to function. |
| |
RS232C SEL | 0000 | OFF: | The |
|
|
| not function. |
| 0001 | ON: | The |
|
| ||
205 | For setting the | ||
| (baud rate). |
| |
BAUD RATE | 0000 | 300 |
|
| 0001 | 600 |
|
| 0002 | 1200 |
|
| 0003 | 2400 |
|
| 0004 | 4800 |
|
| 0005 | 9600 |
|
|
| ||
206 | For setting the | ||
| (Unit: bits) |
| |
DATA | 0000 | 7 |
|
LENGTH | 0001 | 8 |
|
|
| ||
207 | For setting the number of | ||
| (Unit: bits) |
| |
STOP BIT | 0000 | 1 |
|
| 0001 | 2 |
|
|
| ||
208 | For setting whether the | ||
| to be used and, if it is used, whether even or | ||
PARITY | odd parity is to apply. | ||
| 0000 | NON: |
|
| The parity bit is not used. | ||
| 0001 | ODD: |
|
| The parity bit is used with an odd parity. | ||
| 0002 | EVEN: |
|
| The parity bit is used with an even parity. | ||
|
|
|
|
The underlining (__) denotes the factory setting mode.
No./Item |
| Description of setting |
|
| |
|
| |
209 | For setting whether or not to return the ACK | |
| code when a command is received from RS- | |
RETURN ACK | 232C. |
|
| 0000 | OFF: The ACK code is not returned. |
| 0001 | ON: The ACK code is returned. |
|
| |
212 | For selecting the remote control connector | |
| for controlling the slave machine when this | |
MASTER | VTR is to be used as the master machine for | |
PORT | ||
| 0001 | IN/OUT: The IN/OUT connector is used. |
| 0001 | OUT: The OUT connector is used. |
| <Note> |
|
| This setting takes effect only when the 9P button has | |
| been set to LOCAL (LED off). | |
|
|
|
87