Setup menus
<TIME CODE>
No./Item |
| Description of setting | ||
|
| |||
|
| |||
500*4 | For selecting whether or not to output the | |||
| VITC signal at the positions selected by setup | |||
VITC BLANK | menu items No.501 (VITC | |||
| (VITC |
|
| |
| 0000 | BLANK: | The VITC signal is not output. | |
| 0001 | THRU: | The VITC signal is output. | |
| <Note> |
|
|
|
| Only the SD output takes effect at this setting. | |||
|
| |||
501*4 | For setting the position where the VITC signal | |||
| is to be inserted. |
| ||
VITC | <59/60Hz> |
| <50Hz, 25Hz (SD)> | |
| 0000 | 10L | 0000 | 7L |
| : | : | : | : |
| 0006 | 16L | 0004 | 11L |
| : | : | : | : |
| 0010 | 20L | 0015 | 22L |
| <Notes> |
|
|
•The same line as the one selected by the setup menu item No.502 (VITC
•Only the SD output takes effect at this setting.
502*4 | For setting the position where the VITC signal | ||||
| is to be inserted. |
|
| ||
VITC | <59/60Hz> |
| <50Hz, 25Hz (SD)> | ||
| 0000 |
| 10L | 0000 | 7L |
| : |
| : | : | : |
| 0008 |
| 18L | 0006 | 13L |
| : |
| : | : | : |
| 0010 |
| 20L | 0015 | 22L |
| <Notes> |
|
|
| |
| • The same line as the one selected by the setup menu | ||||
| item No.501 (VITC | ||||
| • Only the SD output takes effect at this setting. | ||||
|
| ||||
503*1 | For setting the synchronization of the internal | ||||
| time code generator. |
| |||
TCG MODE | 0000 | REGEN: |
|
| |
| The time code reader is synchronized with the | ||||
| time code which is read from the tape. | ||||
| 0001 |
| PRE: |
|
|
| Presetting is enabled at the operation panel or | ||||
| by the remote controller. |
| |||
| 0002 |
| AUTO: |
|
|
| The REGEN and PRE settings are | ||||
| automatically switched in accordance with the | ||||
| operation mode. |
|
| ||
| In the editing mode: REGEN is selected. | ||||
| In all other modes: PRE is selected. | ||||
|
|
|
| ||
504*1 | For setting when | the | internal time code | ||
| generator is to advance depending on the | ||||
RUN MODE | operation mode. |
|
| ||
| 0000 |
| REC: |
|
|
| The time code generator is advanced during | ||||
| recording. |
|
| ||
| 0001 |
| FREE: |
|
|
| The time code generator is advanced while the | ||||
| power is on regardless of which operation | ||||
| mode is established. |
|
*1: This item is not displayed when the 23/24 Hz or 25 Hz (HD or SD) mode has been selected as the system menu item No.25 (SYSTEM FREQ) setting.
*2: This item is not displayed when the 23/24 Hz or 25 Hz (HD) mode has been selected as the system menu item No.25 (SYSTEM FREQ) setting.
The underlining (__) denotes the factory setting mode.
No./Item |
| Description of setting | |
|
| ||
|
| ||
505*1 | For selecting the regeneration signal when | ||
| REGEN has been selected as the TCG (time | ||
TCG REGEN | code generator) mode. | ||
| 0000 | TC&UB: |
|
| Regeneration applies to both the time code | ||
| and user’s bit. |
| |
| 0001 | TC: |
|
| Regeneration applies only to the time code only. | ||
| 0002 | UB: |
|
| Regeneration applies only to the user’s bit only. | ||
|
| ||
506*1 | For selecting the editing mode range when | ||
| the VTR is operating in the REGEN mode | ||
REGEN MODE | while | performing editing operations with | |
| “AUTO” selected as the setup menu item | ||
| No.503 (TCG MODE) setting. | ||
| 0000 | AS&IN: |
|
| Regeneration applies during assemble or | ||
| insert editing. |
| |
| 0001 | ASSEM: |
|
| Regeneration applies during assemble editing. | ||
| 0002 | INSRT: |
|
| Regeneration applies during insert editing. | ||
|
| ||
507*1 | For selecting the time code to be used when | ||
| HD SDI or SD SDI has been selected as the | ||
TC SOURCE | setup menu item No.600 (VIDEO IN SEL) | ||
| setting when an external time code is to be | ||
| used. |
|
|
| [When HD SDI has been selected] | ||
| 0000 | INT: |
|
| The time code of the internal time code | ||
| generator is used. | ||
| 0001 | EXT_L: |
|
| LTC of the TIME CODE IN connector is used. | ||
| 0002 | SLTC: |
|
| The LTC information added to the serial | ||
| signals which are input to HD SDI IN is used. | ||
| 0003 | SVITC: |
|
| The VITC information added to the serial | ||
| signals which are input to HD SDI IN is used. | ||
| [When SD SDI has been selected] | ||
| 0000 | INT: |
|
| The time code of the internal time code | ||
| generator is used. | ||
| 0001 | EXT_L: |
|
| LTC of the TIME CODE IN connector is used. | ||
| 0002 | VITC: |
|
| The VITC information added to the serial | ||
| signals which are input to SD SDI IN is used. | ||
| <Note> |
|
|
| If the VIDEO IN SEL input selection is changed, the time | ||
| code is converted as shown below. | ||
| [HD_SDI] | [SD_SDI] | |
| INT | ↔ | INT |
| EXT_L | ↔ | EXT_L |
| SLTC | ↔ | EXT_L |
| SVITC | ↔ | VITC |
|
|
|
|
91