■Connection with the Camera Site
●System Camera Connection
Connect system cameras to VIDEO IN
IN | 8 | 7 | 6 |
OUT | 8 | 7 | 6 |
●Data-multiplex Camera Connection
Connect combination cameras directly to VIDEO IN
■Connection with the Monitors
Connect the spot and multiscreen monitors.
Disk Recorder
SPOT
OUT
MULTI
SCREEN OUT
Spot Monitor | Multiscreen Monitor |
■ALARM/REMOTE Connection
Unit as shown below.
Pan/Tilt Table
Receiver
POWER
ON
OFF
IN | 8 | 7 |
OUT | 8 | 7 |
Combination Cameras
ALARMData Multiplex
ALARM SUSPEND
Unit
Data Multiplex Unit
RS485 Cable
6 | 5 | 4 |
DATA
654 VIDEO
A
| 13 |
|
|
| 1 |
| 25 | ALARM/REMOTE | 14 | ||
|
|
| |||
Pin | Designation | Pin |
| Designation | |
# | # |
| |||
|
|
|
| ||
1 | Alarm Reset In |
| 14 | Time Adjust Out | |
2 | Alarm In 1 |
| 15 | Alarm In 5 | |
3 | Alarm In 2 |
| 16 | Alarm In 6 | |
4 | Alarm Recovery Out *1 | 17 | Alarm In 7 | ||
5 | Alarm Recovery Out 2 | 18 | Alarm In 8 | ||
6 | Alarm Out 1 |
| 19 | Signal GND | |
7 | Alarm Out 2 *2 |
| 20 | Signal GND | |
8 | Disk End Out |
| 21 | Play Status Out | |
9 | Warning Out |
| 22 | EXT REC MODE In | |
10 | Alarm In 3 |
| 23 | No Connection | |
11 | Alarm In 4 |
| 24 | Sequence In | |
12 | REC Status Out |
| 25 | Sequence Out | |
13 | Time Adjust In |
|
|
|
|
16