Panasonic WJ-HD220 Protocol Selection Protocol Select, Baud Rate Baud Rate, Data Bit Data BIT

Models: WJ-HD220

1 103
Download 103 pages 24.68 Kb
Page 67
Image 67

Communication Setup

(COMMUNICATION SETUP)

Click the [SERIAL PORT SETUP] or [NETWORK SETUP] button. The respective window opens.

Serial Port Setup

(SERIAL PORT SETUP)

8Protocol Selection (PROTOCOL SELECT)

PSDATA: Select when the communication chain uses the PSDATA protocol.

When selected, the DATA terminal on the rear panel can be used.

RS-232C:Select when other than PSDATA is used. When selected, the RS-232C terminal on the rear panel can be used.

8Baud Rate (BAUD RATE)

4800: 4 800 bps

9600: 9 600 bps

19200: 19 200 bps

8Data Bit (DATA BIT)

7:7 bits

8:8 bits

8Parity Check (PARITY CHECK)

NONE: No parity check

EVEN: Even parity

ODD: Odd parity

8Stop Bit (STOP BIT)

1 bit: 1 bit

2 bit: 2 bits

8Wait Time (WAIT TIME)

OFF: Retransmission is disabled.

100 MSEC: 100 m seconds

200 MSEC: 200 m seconds

1 SEC: 1 second

8Control Unit Addresses

(CONTROL UNIT ADDRESS) (only for PSDATA)

Assignable address: From 1 to 99, must be unique in the chain.

8System Unit Address (SYSTEM UNIT ADDRESS) (only for PSDATA)

Assignable addresses: From 1 to 99, must be unique in the chain.

8Alarm Data (ALARM DATA)

OFF: Select this when no system controller is connect- ed.

0 SEC: Does not pause.

1 SEC: Pauses for 1 second.

5 SEC: Pauses for 5 seconds.

Click the [SET] button when all items have been set proper- ly.

Click the [CAMERA SYSTEM SETUP] button. The CAMERA SYSTEM SETUP window opens.