Monitor Images on a PC

The following are descriptions of how to monitor images from the unit on a PC.

Monitor images from a single camera

Step 1

Start up the web browser.

Step 2

Enter the IP address designated using the Panasonic IP setup software in the address box of the browser. (Example: http://192.168.0.10/)

Important:

When the HTTP port number is changed from "80", enter "http://IP address of the unit +: (colon) + port number" in the address box of the browser, for example, "http://192.168.0.11:8080".

When the PC is in a local network, configure the web browser to bypass the proxy server for the local address.

Step 3

Press the [Enter] key on the keyboard.

The "Live" page will be displayed.

Important:

Follow the instructions on page 69 when the mes- sage is displayed on the information bar of the browser.

Notes:

When "ON" is selected for "User Authentication", the authentication window will be displayed before dis- playing live images for the user name and password

entries. The default user name and password are as follows.

User name: admin

Password: 12345

When accessing the unit without changing the default password, the pop-up window saying that it is recommended to change the password will be dis- played.

To enhance the security, change the password for the user "admin". It is recommended to change this password periodically. (page 46)

When "Unicast port (AUTO)" or "Unicast port (MAN- UAL)" is selected for "Transmission type" (page 28), up to 8 users per channel (up to 16 users for the total of all the channels) can access the unit concur- rently. Depending on the set values for "Total bit rate" and "Max bit rate (per 1 client)", the maximum concurrent access number may be limited. When 8 users have been concurrently accessing already, the access limit message will be displayed for users who accessed subsequently.

When "ON" is selected for "MPEG-4 transmission" (page 24), an MPEG-4 image will be displayed. When "OFF" is selected, a JPEG image will be dis- played. It is possible to display JPEG image even when "ON" is selected for "MPEG-4 transmission". In this case, the refresh interval will be lowered to approx. half the set value.

<Refresh interval (JPEG)>

When "ON" is selected for "MPEG-4 transmission" JPEG (VGA): 15 fps

JPEG (QVGA): 60 fps

These are the total maximum values of all the chan- nels.

The refresh interval may be longer depending on a network environment, PC spec, photographic sub- ject, access traffic, etc.

Important:

When displaying multiple MPEG-4 images on a PC, images may not be displayed depending on the per- formance of the PC.

Refer to the next page for further information about the "Live" page.

4

Page 4
Image 4
Panasonic WJ-NT314 manual Monitor Images on a PC, Monitor images from a single camera, Step, Refresh interval Jpeg