Configure the settings relating to the alarm out connector [Alarm output setup]
Click the [Alarm] tab on the "Alarm setup" page. (☞ page 40)
The settings relating to the alarm output terminals (Alarm Output No. 1 to 4) can be configured on this page. Alarm Output No. 1 to 4 is associated with each alarm input of CH1 to 4. Refer to pages 40 and 42 for further information about the settings relating to the alarm action and the alarm image.
Note:
When "OPEN" is selected, the alarm signal will be output for around 90 seconds when the power of the unit is turned on.
[Pulse width]
When "Pulse" is selected for "Alarm output", select an alarm output terminal duration from the following. Available value: 1 - 120 sec
Default setting: 1 sec
■Alarm output terminal setup
Select a desired alarm output terminal number from the
[Alarm output setup]
Select "ON" or "OFF" to determine whether or not to output the alarm signals to the alarm out connector when an alarm is detected.
Default setting: OFF
[External terminal output setup]
Select "Latch" or "Pulse" for the alarm output terminal at an alarm occurrence.
Latch: When an alarm is detected, alarm output con- nector will be in the state selected for "Alarm output" until the alarm occurrence indication button is clicked.
Pulse: When an alarm is detected, the alarm output ter- minal will be in the state to the "Alarm output" setting for the period set for "Pulse width".
Default setting: Latch
[Alarm output]
Select "OPEN" or "CLOSE" to determine whether to open or close the alarm output connector when output the alarm signals.
OPEN: The alarm out connector will open when output the alarm signals. (Normally close)
CLOSE: The alarm out connector will close when output the alarm signals. (Normally open)
Default setting: CLOSE
■AUX name
The names of "AUX", "OPEN" and "CLOSE" on the "Live" page can be changed.
[AUX (Up to 10 characters)]
Enter the name for "AUX" on the "Live" page. Number of characters that can be entered: 1 - 10
characters
Default setting: AUX
[OPEN (Up to 5 characters)]
Enter the name for "OPEN" of "AUX" on the "Live" page. Number of characters that can be entered: 1 - 5 char-
acters
Default setting: OPEN
[CLOSE (Up to 5 characters)]
Enter the name for "CLOSE" of "AUX" on the "Live" page.
Number of characters that can be entered: 1 - 5 char-
acters
Default setting: CLOSE
43