COMSPHERE 3000 Series Carrier
Installation
To install the SDU in its dedicated slot in the carrier (Slot 0):
.Procedure
1.Set the carrier address DIP switches
a.For a single carrier, leave the switches set for Carrier 1, which is the factory default.
b.To populate a new cabinet with an NMS control channel dedicated to DSUs, use the Carrier 1 setting for the first carrier, usually at the bottom of the cabinet. Use the Carrier 2 setting for the next carrier up from the bottom. Continue to the Carrier 6 setting, if necessary, for the top carrier. If there are more than eight carriers in a single installation, continue with the Carrier 7 and Carrier 8 settings for the
second cabinet. The next COMSPHERE
3000 Series Carrier is numbered 1, but is on a different control channel.
c.To add a COMSPHERE 3000 Series Carrier to an existing control channel, use Table
d.Write the carrier number on the slot label for the SDU (slot labels are located under each slot on the SDCP or cover plate).
2.Set the protocol DIP switches
Table
Carrier Address DIP Switches
Switch |
|
|
| Carrier Address |
|
|
| ||
|
|
|
|
|
|
|
| ||
11 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | ||
| |||||||||
S2 ± 4 | Ð | Ð | Ð | Ð | Ð | Ð | Ð | Ð | |
|
|
|
|
|
|
|
|
| |
S2 ± 3 | Off | Off | Off | Off | ON | ON | ON | ON | |
|
|
|
|
|
|
|
|
| |
S2 ± 2 | Off | Off | ON | ON | Off | Off | ON | ON | |
|
|
|
|
|
|
|
|
| |
S2 ± 1 | Off | ON | Off | ON | Off | ON | Off | ON | |
|
|
|
|
|
|
|
|
|
1 Factory default setting:
ON is to the left as you face the rear of the carrier. Off is to the right.