COMSPHERE 3000 Series Carrier

Figure 3-38. Cabling and Ferrite Chokes

To install the ferrite choke, refer to Figure 3-38:

.Procedure

1.Open the ferrite choke and place it around the ac power cable as close to the cable connector as possible.

2.Close the two halves around the cable and snap the choke shut, pressing down on the plastic latch to secure it in place.

3.Secure the ferrite choke in place with the cable tie that is supplied.

Non-Modular Circuit Card Installation

To install each circuit card, proceed as follows, referring to the appropriate Installation and Operation Manual or Applications Guide when necessary:

.Procedure

1.Change any default hardware strap settings that may be required before installing the circuit card in the carrier.

2.Using a Phillips screwdriver, loosen the screw holding the circuit pack lock and rotate the lock to the open position (refer to Figure 3-16). Open the latch.

3-52

December 1994

3000-A2-GA31-80

Page 79
Image 79
Paradyne 3000 manual Non-Modular Circuit Card Installation, Cabling and Ferrite Chokes