MIB Descriptions

Table C-9. Asynchronous Port Table Objects (2 of 2)

Object

Description

Setting/Contents

 

 

 

rs232AsyncPort

Specifies the type of parity

Supports only the following values:

Parity

used by the port.

none(1) ± No parity bit

(rs232Async

 

 

 

PortEntry 4)

 

odd(2) ± Odd parity

 

 

even(3) ± Even parity

 

 

 

rs232AsyncPort

Specifies the ability to

Supports only the following values:

AutoBaud

automatically sense the

disabled(2) ± Does not support

(rs232Async

input speed of the port.

Autobaud.

PortEntry 5)

 

 

 

 

 

 

Synchronous Port Table Objects

The Synchronous Port Table Objects contains an entry for the synchronous user data port and the Management port when this port is configured for synchronous operation. For this unit, entries in the table that are counters (rs232SyncPortEntry 3±7) are used to collect statistics only and are not supported. Clarification for objects contained in this table as it applies to the unit is provided below.

Table C-10. Synchronous Port Table Objects (1 of 2)

Object

Description

Setting/Contents

 

 

 

rs232SyncPort

Specifies the clock source

Supports only the following values:

ClockSource

for the port.

internal(1) ± The port uses an internal

(rs232Sync

 

 

clock.

PortEntry 2)

 

 

 

 

 

split(3) ± The port uses an external

 

 

transmit clock and internal receive clock.

 

 

 

rs232SyncPort

Specifies whether this

Supports only the following value:

Role

device interface is a DTE or

dce(2) ± The port acts as a DCE.

(rs232Sync

DCE.

 

PortEntry 8)

 

 

 

 

 

rs232SyncPort

Specifies the bit encoding

Supports only the following value:

Encoding

technique that this port

nrz(1) ± The port uses non-return to

(rs232Sync

uses.

zero encoding.

PortEntry 9)

 

 

 

 

 

 

rs232SyncPort

Specifies the method used

Supports only the following values:

RTSControl

to control the RTS signal.

controlled(1) ± For User Data port, this

(rs232Sync

Refer to Data Port Options,

value is used when the Data Port option

PortEntry 10)

Table A-3.

Carrier Control by RTS is set to

 

 

 

 

Switched.

 

 

constant(2) ± For User Data port, this

 

 

value is used when the Data Port option

 

 

Carrier Control by RTS is set to

 

 

Constant. This is the only valid value for

 

 

the Management port.

 

 

 