MIB Descriptions

Output Signal Table Objects

The Output Signal Table Objects contains entries for the output signals that can be asserted by the unit, for the synchronous User Data port. Clarification for objects contained in this table as it applies to the unit is provided below.

Table C-12. Output Signal Table Objects

Object

Description

Setting/Contents

 

 

 

rs232OutSigName

Contains the identification

Supports only the following

(rs232OutSigEntry 2)

of a hardware output signal.

values:

 

 

cts(2) ± Clear To Send

 

 

dsr(3) ± Data Set Ready

 

 

dcd(6) ± Received Line Signal

 

 

Detector

 

 

 

rs232OutSigState

Contains the current signal

Supports only the following

(rs232OutSigEntry 3)

state.

values:

 

 

on(2) ± The signal is asserted

 

 

off(3) ± The signal is deasserted

 

 

 

rs232OutSigChanges

Indicates the number of

Increments the object each time

(rs232OutSigEntry 4)

times that a signal has

that the signal is sampled (every

 

changed from on to off, or

100 ms) and the signal state is

 

off to on.

different from the previous state.

 

 

 

7610-A2-GB20-10

November 1997

C-17

Page 110
Image 110
Paradyne SNMP DSU, 7610 manual Output Signal Table Objects, Rs232OutSigEntry