Configuration Option Tables

Table A-1. System Options (3 of 3)

Test Timeout

Possible Settings: Enable, Disable

Default Setting: Enable

Allows user-initiated tests to end automatically. Recommend enabling when the unit is managed remotely through the IMC to avoid the requirement to terminate the test manually.

Enable ± User-initiated loopback and pattern tests end when test duration is reached.

Disable ± Tests can be terminated manually from the Network Tests screen. Refer to the Network Tests section of Chapter 7.

NOTE: Tests commanded by the DTE or network-initiated tests are not affected by this test timeout.

Test Duration (min)

Possible Settings: 1±120

Default Setting: 10

Number of minutes for a test to be active before automatically ending.

HTest Duration (min) option appears when Test Timeout is enabled.

1 to 120 ± Amount of time in minutes for a user-initiated test to run before terminating.

Security Violation Alarm

Possible Settings: Enable, Disable

Default Setting: Enable

Issues an alarm when access to the unit is attempted and fails.

Enable ± Alarm generated when a security violation is detected. Refer to the Trap: authentificationFailure section of Appendix D for possible alarm causes.

Disable ± No alarm generated for a security violation.

A-4

November 1997

7610-A2-GB20-10

Page 63
Image 63
Paradyne 7610, SNMP DSU manual Table A-1. System Options 3, Test Timeout, Test Duration min, Security Violation Alarm