Configuration Option Tables

Table A-6. External Device Options (3 of 3)

Disconnect String

Possible Settings: ASCII Text, Clear

Default Setting: [blank]

The Disconnect String specifies the command used to disconnect an external device. The external device must be in command mode, so the Escape Sequence is always sent before the Disconnect String.

HDisconnect String option appears when External Device Commands is set to Other.

ASCII Text ± Enter a maximum of 20 characters. Refer to the ASCII Characters section for valid ASCII characters and control sequences.

Clear ± Clears the field and sets to no string. The Management port DSR lead is used to force a disconnect.

Telnet Session Options

To access the Telnet Session Options screen, follow this menu selection sequence:

Main Menu Configuration Load Configuration From Edit

User Interface Telnet Session

Table A-7. Telnet Session Options (1 of 2)

Telnet Session

Possible Settings: Enable, Disable

Default Setting: Disable

Specifies if the DSU will respond to a Telnet session request from a Telnet client on an interconnected IP network.

Enable ± Allows Telnet sessions between the unit and a Telnet client.

Disable ± No Telnet sessions allowed.

Login Required

Possible Settings: Enable, Disable

Default Setting: Disable

Used to secure access to the ATI through a Telnet session. Login IDs are created with a password and access level. Refer to the Creating a Login section of Chapter 4.

Enable ± Security is enabled. When access is attempted via Telnet, the user is prompted for a Login ID and password.

Disable ± No Login required for a Telnet session.

A-18

November 1997

7610-A2-GB20-10

Page 77
Image 77
Paradyne 7610, SNMP DSU Table A-6. External Device Options 3, Table A-7. Telnet Session Options 1, Disconnect String