Messages and Troubleshooting

Configuring SNMP Traps

An SNMP trap can be automatically sent out the IMC or the Management port to the SNMP manager when the DSU detects conditions set by the user. These traps enable the SNMP manager to gauge the state of the network. Refer to Standards Compliance for SNMP Traps, Appendix D, for details of SNMP traps supported by the DSU.

To configure the DSU for SNMP traps, use the SNMP Traps Options screen to:

￿Enable SNMP traps.

￿Set the number of SNMP managers that receive SNMP traps from the DSU.

￿Enter an IP address and network destination for each SNMP manager specified.

￿Select the type of SNMP traps to be sent from the DSU.

To configure SNMP Traps, follow this menu selection sequence:

Main Menu Configuration Load Configuration From Edit

SNMP & Communication SNMP Traps

Refer to SNMP Traps Options, Table A-12.

Dialing Out SNMP Traps

Configure the SNMP traps before performing this procedure.

"Procedure

1.Configure the phone directories to use when dialing out SNMP traps through the Management port and a connected external device. Refer to the Call Setup section in Chapter 3.

2.Use the Alarms & Traps Options to enable the DSU's automatic call initiation to a remote device with Alarm & Trap Dial-Out, Call Retry, and Alternate Dial-Out Directory. Follow this menu selection sequence:

Main Menu Configuration Load Configuration From Edit

Alarms & Traps

Refer to Alarms & Traps Options, Table A-8.