Testing

Refer to Terminal Port Options, Table A-4. To reset Terminal port settings:

"Procedure

1.At the async terminal connected to the Terminal port, verify that the Terminal port options are set to the default settings:

ÐData Rate(Kbps) to 9.6

ÐCharacter Length to 8

ÐStop Bits to 1

ÐParity to None

2.Power the DSU Off and back On. The DSU performs a power-up routine.

3.Immediately after the OK LED turns on, press the Return key 5 times quickly in succession. The System Paused screen appears.

4.Tab to the desired method, and enter yes (or y) for the selected prompt.

If entering yes to prompt . . .

Then all . . .

 

 

Reset Terminal Port Options

Terminal port options are set to their factory

 

default values. Refer to Terminal Port Options,

 

Table A-4.

 

 

Reload Factory Defaults

Factory default settings contained in the Default Factory Configuration area are loaded in Current, Customer 1, and Customer 2 configuration areas.

Any changes to configuration and control settings will be replaced by the factory defaults.

If no (or n) is entered, or if no selection is made within 30 seconds, the DSU returns to the condition or operation it was in when the system pause was initiated, with the Terminal port data rate returning to its configured rate.

5.If yes (or y) is entered, the DSU resets itself and initiates a Device Self-Test. Connectivity is restored and the Main Menu screen appears.

7-8

November 1997

7610-A2-GB20-10

Page 53
Image 53
Paradyne 7610, SNMP DSU manual If entering yes to prompt Then all