Configuration Option Tables

Table A-2. Network Interface Options (3 of 4)

No Signal Alarm

Possible Settings: Enable, Disable

Default Setting: Enable

When a NS condition is detected on the network interface, an ASCII alarm is generated.

Enable ± Generates an ASCII alarm when a no signal condition is detected.

Disable ± No ASCII alarm is generated.

NOTE: Additional settings are required to send out an ASCII alarm. Refer to the Alarm Messages section in Chapter 8.

Out of Service Alarm

Possible Settings: Enable, Disable

Default Setting: Enable

When an OOS condition is detected on the network interface, an ASCII alarm is generated.

HOut of Service Alarm option appears when the Operating Mode is set to DDS in Table A-1.

Enable ± Generates an ASCII alarm when an out of service condition is detected.

Disable ± No ASCII alarm is generated.

NOTE: Additional settings are required to send out an ASCII alarm. Refer to the Alarm Messages section in Chapter 8.

Out of Frame Alarm

Possible Settings: Enable, Disable

Default Setting: Enable

When an OOF condition is detected on the network interface, an ASCII alarm is generated.

Enable ± Generates an ASCII alarm when an out of frame condition is detected on the network interface.

Disable ± No ASCII alarm is generated.

NOTE: Additional settings are required to send out an ASCII alarm. Refer to the Alarm Messages section in Chapter 8.

Excessive BPV Alarm

Possible Settings: Enable, Disable

Default Setting: Enable

When a Bipolar Violation condition is detected on the network interface, an ASCII alarm is generated.

Enable ± Generates an ASCII alarm when an excessive BPV condition is detected.

Disable ± No ASCII alarm is generated.

NOTE: Additional settings are required to send out an ASCII alarm. Refer to the Alarm Messages section in Chapter 8.

7610-A2-GB20-10

November 1997

A-7

Page 66
Image 66
Paradyne SNMP DSU, 7610 Table A-2. Network Interface Options 3, No Signal Alarm, Out of Service Alarm, Out of Frame Alarm