Monitoring the DSU

Self-Test Results

The results of the last power-up or reset self-test appear in the middle column of the System and Test Status screen.

Table 6-2. Self-Test Results Messages

Message

What Message Indicates

What To Do

 

 

 

Device Fail

One or more of the DSU's integrated

1. Reset the DSU and try again.

 

circuit chips has failed device-level

2. Call your service

 

testing.

 

representative for assistance if

 

 

Memory Fail

DSU failed memory verification.

the message reappears.

 

 

 

 

Passed

The DSU has been plugged in or

No action needed.

 

reset and has passed the diagnostic

 

 

test. There are no other status

 

 

messages.

 

 

 

 

Network Interface Status

The network interface status fields are read-only:

HLine Rate (Kbps). If the DSU is connected to an operating line and the Line Rate (Kbps) shows Autobaud and does not change to a line rate within about 25 seconds, Line Rate (Kbps) may have to be reconfigured manually. Refer to System Options, Table A-1.

HLoop Loss (dB). The loop loss is the loss of signal strength of the receive line signal from the local loop.

To view the Network Interface Status, follow this menu selection sequence:

Main Menu Status Network Interface Status

Table 6-3. Network Interface Status Screen Contents

Field

Status

What the Status Indicates

Line Rate (Kbps)

56Kbps

64CC

64LADS Autobaud

Line rate on the network interface. Autobaud indicates the DSU is trying to determine the network line rate. This should be a temporary condition.

No Signal

No signal can be detected over the network interface.

Loop Loss (dB)

0 to ±65 dB

Amount of loop loss ± loss of signal strength of the receive line signal from the local loop, measured in decibels.

Inoperative

The line may be disconnected.

7610-A2-GB20-10

November 1997

6-7

Page 44
Image 44
Paradyne SNMP DSU, 7610 manual Network Interface Status, Self-Test Results