Testing
7-2 7610-A2-GB20-10
November 1997
Tests Available
From the Test menu, you can run network tests, data port tests, and a lamp test
for the front panel LEDs. Loopbacks can be initiated locally and remotely. Refer to
Loopbacks, Table 7-2.
The Test menu is limited to users with an access level of 1 or 2. To access the
Test menu, follow this menu selection sequence:
Main Menu
Test
Network tests require the participation of your network service provider.
The DSU supports physical-level tests independently on a per-interface basis.
The CSU and DSU loopbacks and 511 test pattern send/monitor are
supported on the network interface.
The Local Loopback and 511 test pattern send/monitor are supported on the
DTE port.
Network Tests
To access the Network Tests screen, follow this menu selection sequence:
Main Menu
Test
Network Tests
main/test/network
Device Name: Model: 7610
NETWORK TESTS
Test Command Status Result
CSU Loopback: Start Inactive 0:00:00
DSU Loopback: Start Inactive 0:00:00
Send V.54 Up: Send Sending
Send V.54 Down: Send Inactive
Send 511: Start Inactive 0:00:00
Monitor 511: Stop Active 125:08:48 Errors 99999+
––––––––––––––––––––––���–––––––––––––––––––––––––––––––––––––––––––––––––––––––––
Ctrl-a to access these functions, ESC for previous menu MainMenu Exit
ResetMon
Use the Command column to start or stop a test by pressing Enter. The Result
column displays the test duration since the last device reset. When the Monitor
511 test is active, ResetMon is available to reset the error counter to zero.
Selecting the Stop command on the Network Test screen or Abort All Tests from
the Test menu will not disrupt a network-initiated loopback.