Configuration Option Tables

Alarms & Traps Options Menu

For Alarms & Traps Options, refer to Table A-8. To access the Alarms & Traps Options screen, follow this menu selection sequence:

Main Menu Configuration Load Configuration From Edit

Alarms & Traps

Table A-8. Alarms & Traps Options (1 of 2)

ASCII Alarm Messages

Possible Settings: Enable, Disable

Default Setting: Disable

Controls the generation and routing of ASCII alarm messages to an ASCII terminal or printer connected to the Management port. Refer to the Alarm Messages section of Chapter 8.

Enable ± ASCII alarm messages are generated and sent out when the Management port is configured for Alarms in Management Port Options, Table A-5.

HThe messages are sent out immediately if there is:

±No DCE (e.g., modem or PAD) connected to the Management port and External Device Commands option is set to Disable in Table A-6 or

±An active connection is already established via an external DCE.

HIf an external device is connected to the Management port with no active connection, the message control is based on the next option, Alarm & Trap Dial-Out. External Device Commands must be configured for AT or Other in External Device Options, Table A-6.

Disable ± ASCII alarm messages are not generated or sent.

Alarm & Trap Dial-Out

Possible Settings: Enable, Disable

Default Setting: Disable

When there is no active connection, this option controls whether generating an ASCII alarm or SNMP trap results in automatic call initiation.

Enable ± Automatically places a call via the external device connected to the

Management port.

HTo send out SNMP traps, SNMP Management must be enabled in Table A-10.

HWhen Port Use is set to Net Link in Table A-5, up to ten SNMP traps are queued at the interface.

HThe Primary Directory phone number is dialed. Refer to the Call Setup section of Chapter 3.

HRefer to the Call Retry option for handling of incomplete call attempts.

Disable ± Automatic call initiation is disabled and alarm messages are discarded.

SNMP traps are retained until a connection is established.

A-20

November 1997

7610-A2-GB20-10

Page 79
Image 79
Paradyne 7610, SNMP DSU manual Alarms & Traps Options Menu, Table A-8. Alarms & Traps Options 1, Ascii Alarm Messages