HOW TO REPLACE THE FUSE IN A POWER SUPPLY MODULE

The matrix bay is shipped from the factory configured for the correct input power. The power input panel, on the rear panel of the matrix bay, provides two separate power input receptacles, one for each power supply.

NOTE: The power input panel is not serviceable and should be removed or installed only by Pelco.

Each power input receptacle is equipped with a fuse assembly. In addition, each fuse assembly also provides a spare fuse. Refer to Figure 18. WARNING: Always replace blown fuses with fuses of the same rating. Failure to do so could result in serious damage to the unit.

1.Remove the power cord from the power input receptacle.

2.Using a small screwdriver, pry the fuse holder out of the socket. The complete fuse assembly comes out of the unit.

3.Replace the fuse using a 1.6 ASB fuse. If using the spare, be sure to replace the spare with one of the same rating.

4.Plug the power cord into the power input receptacle.

FUSE HOLDER

REPLACE

IF NECESSARY

SPARE FUSE

Figure 18. How to Replace a Power Supply Fuse