Administrator’s Guide - SoundPoint IP / SoundStation® IP Optimization
140 Copyright © 2006 Polycom, Inc.

4.6.1.19.2 Scheduled Logging Parameters <scheduled/>

The phone can be configured to schedule certain advanced logging tasks on a periodic

basis. These attributes should be set in consultation with Polycom. Each scheduled log

task is controlled by a unique attribute set starting with log.sched.x where x identifies

the task.

4.6.1.20 Security <security/>

These settings affect security aspects of the phone.

Attribute
Permitted
Values Interpretation
log.sched.x.name alphanu-
meric string Name of an internal system command to be periodically
executed. To be supplied by Polycom.
log.sched.x.level 0-5 Event class to assign to the log events generated by this
command. This needs to be the same or higher than
log.level.change.slog for these events to appear in the log.
log.sched.x.period positive
integer Seconds between each command execution. 0=run once
log.sched.x.startMode abs, rel Start at absolute time or relative to boot.
log.sched.x.startTime positive
integer OR
hh:mm
Seconds since boot when startMode is rel or the start time
in 24-hour clock format when startMode is abs.
log.sched.x.startDay 1-7 When startMode is abs, specifies the day of the week to
start command execution. 1=Sun, 2=Mon, ..., 7=Sat
Attribute
Permitted
Values Default Interpretation
sec.tagSerialNo 0, 1 0 If set to 1, the phone may advertise its serial num-
ber (Ethernet address) through protocol signaling.