4.6.1.18.4.1 LEDs <led/>

In the following table, x is the LED number.

Attribute

Permitted

Interpretation

Values

 

 

 

ind.led.x.index

 

This is for internal usage only and should not be changed

 

 

(this is the logical index).

 

 

 

ind.led.x.class

positive integer

Assigns the class (defined in 4.6.1.18.3 Classes <Classes/

 

 

> on page 135) for this indicator.

 

 

 

ind.led.x.physNum

 

This maps the logical index to a specific physical LED.

 

 

 

4.6.1.18.4.2Graphic Icons <gi/> <IP_300/>, <IP_400/>, <IP_500/>, <IP_600/> and <IP_4000/>

In the following table, x=IP_300, IP_400, IP_500, IP_600 or IP_4000, y is the graphic icon number. Note that IP_300 parameters affect SoundPoint® IP 300 and 301 phones, IP_400 parameters affect SoundPoint® IP 430 phones, IP_500 parameters affect SoundPoint® IP 500 and 501 phones, and IP_600 parameters affect SoundPoint® IP 600 and 601 phones.

Attribute

Permitted

Interpretation

Values

 

 

 

ind.gi.x.y.index

 

This is for internal usage only and should not be changed

 

 

(this is the logical index).

 

 

 

ind.gi.x.y.class

positive integer

Assigns the class (defined in 4.6.1.18.3 Classes <Classes/

 

 

> on page 135) for this indicator.

 

 

 

ind.gi.x.y.physX

IP 300: 0-19

For GraphicIcon type indicators, this is the x-axis loca-

 

IP 400: 0-122

tion of the upper left corner of the indictor measured in

 

pixels from left to right.

 

IP 500: 0-159

 

 

 

IP 600: 0-319

 

 

IP 4000: 0-247

 

 

 

 

ind.gi.x.y.physY

IP 300: 0-3

For GraphicIcon type indicators, this is the y-axis loca-

 

IP 400: 0-45

tion of the upper left corner of the indicator measured in

 

pixels from top to bottom.

 

IP 500: 0-79

 

 

 

IP 600: 0-159

 

 

IP 4000: 0-67

 

 

 

 