Attribute

Permitted

Interpretation

Values

 

 

 

ind.gi.x.y.physW

IP 300: n/a

For GraphicIcon type indicators, this is the width of the

 

IP 400: 1-94

indicator measured in pixels.

 

 

 

IP 500: 1-160

 

 

IP 600: 1-320

 

 

IP 4000: 1-248

 

 

 

 

ind.gi.x.y.physH

IP 300: n/a

For GraphicIcon type indicators, this is the height of the

 

IP 400: 1-23

indicator measured in pixels.

 

 

 

IP 500: 1-80

 

 

IP 600: 1-160

 

 

IP 4000: 1-68

 

 

 

 

4.6.1.19 Event Logging <logging/>

Important

Logging parameter changes can impair system operation. Do not change any logging parameters with- out prior consultation with Polycom Customer Support.

The event logging system supports the following classes of events:

Level

Interpretation

 

 

0

Debug only

 

 

1

High detail event class

 

 

2

Moderate detail event class

 

 

3

Low detail event class

 

 

4

Minor error - graceful recovery

 

 

5

Major error - will eventually incapacitate the system

 

 

6

Fatal error

 

 

Each event in the log contains the following fields separated by the character:

time or time/date stamp

1-5 character component identifier (such as “so”)

event class

cumulative log events missed due to excessive CPU load

free form text - the event description