Administrator’s Guide - SoundPoint IP / SoundStation® IP

Optimization

Example:

011511.006so 200soCoreAudioTermChg: chassis -> idle

time stamp

ID

event class missed events text

Three formats are available for the event timestamp:

Type

Example

 

 

 

 

 

0

- seconds.milliseconds

011511.006

-- 1 hour, 15 minutes, 11.006 seconds

 

 

since booting.

 

 

 

 

 

1

- absolute time with minute resolution

0210281716

-- 2002 October 28, 17:16

2

- absolute time with seconds resolution

1028171642

-- October 28, 17:16:42

4.6.1.19.1 Basic Logging <level/><change/> and <render/>

 

Permitted

 

 

Attribute

Values

Default

Interpretation

 

 

 

 

log.level.change.xxx

0-5

4

Control the logging detail level

 

 

 

for individual components.

 

 

 

These are the input filters into

 

 

 

the internal memory-based log

 

 

 

system.

 

 

 

 

log.render.level

0-6

1

Specifies the lowest class of

 

 

 

event that will be rendered to

 

 

 

the log files. This is the output

 

 

 

filter from the internal mem-

 

 

 

ory-based log system.

 

 

 

 

log.render.type

0-2

2

Refer to above table for times-

 

 

 

tamp type.

 

 

 

 

log.render.realtime

0, 1

1

Set to 1.

 

 

 

Note: Polycom recommends

 

 

 

that you do not change this

 

 

 

value.

 

 

 

 